Oklahoma Compliance Guide

Complete guide to Oklahoma UST compliance requirements. OCC licensing, ODAFF Weights & Measures, Class A/B/C operator training, and common violations to avoid.

Key Contacts

Oklahoma Corporation Commission

Petroleum Storage Tank Division (PSTD)

405-521-4683

UST licensing, registration, compliance, LUST cleanup

Oklahoma Corporation Commission

PST Scheduling (Equipment Tests)

405-521-4683

Schedule witnessed tests: drop tubes, overfill, spill buckets, containment sumps

Oklahoma Corporation Commission regulates underground storage tanks through the Petroleum Storage Tank Division (PSTD). All individuals performing UST installation, removal, or testing must hold valid OCC licenses.

  • Individual licenses required for UST work (Installer, Remover, Tester)
  • Minimum 2 years experience required for all license types
  • Must pass OCC written examinations
  • Effective Oct 1, 2024: Anyone performing UST/AST testing must be OCC-licensed
  • License violations can result in fines and work stoppage orders

Important Dates

Oct 1, 2024 - Enhanced testing license requirements effective

License Requirements

UST Installer

Required for installing underground storage tanks and piping

$100 application fee

Requirements

  • Minimum 2 years experience in UST work
  • Pass OCC written examination
  • Submit application with work history
  • Background check
  • $25,000 surety bond (company)

Renewal: Every 3 years with CEU requirements

UST Remover

Required for removing underground storage tanks

$100 application fee

Requirements

  • Minimum 2 years experience
  • Pass OCC examination
  • Valid installer license recommended
  • Safety training documentation

Renewal: Every 3 years

UST Tester

Required for tank testing, line testing, and cathodic protection

$100 application fee

Requirements

  • Minimum 2 years experience OR manufacturer training
  • Pass OCC examination
  • Equipment certification documentation
  • Calibration records for testing equipment

Renewal: Every 3 years

Registered Service Technician (W&M)

Required for dispenser meter calibration and repair

No fee for registration

Requirements

  • Register with ODAFF
  • Training documentation (PEI, manufacturer, or equivalent)
  • Submit Placed-in-Service reports after work
  • Access to certified test measures

Renewal: Annual registration

Class A/B/C Operator

Required for each UST facility - EPA federal mandate

Varies by training provider ($50-200)

Requirements

  • Complete OCC-approved training course
  • Pass operator examination
  • Designate Class A, B, and C operators for each site
  • Maintain training records on-site

Renewal: Class A/B: Every 3 years, Class C: As needed

Compliance Checklist

Licenses & Registration

TaskFrequency
Verify all technician OCC licenses currentQuarterly
Confirm company registration with OCC PSTDAnnual
Check W&M service technician registrationAnnual
Update Class A/B/C operator designationsAs needed

Equipment Testing

TaskFrequency
Schedule drop tube/overfill tests with OCC (PSTscheduling@occ.ok.gov)Before testing
Spill bucket tightness testingEvery 3 years
Containment sump testingEvery 3 years
Post-repair overfill verification testAfter any repair
File test results with OCCWithin 30 days

Site Compliance

TaskFrequency
Conduct monthly equipment inspectionsMonthly
Review and document ATG alarmsWeekly
Annual line/tank testing (if required)Annual
CSLD report review and filingMonthly

Documentation

TaskFrequency
File Placed-in-Service reports after calibrationAs needed
Maintain 3-year inspection record archiveOngoing
Keep operator training certificates on-siteOngoing
Document all UST work with OCCWithin 30 days

All Regulatory Contacts

Oklahoma Corporation Commission

Petroleum Storage Tank Division (PSTD)

UST licensing, registration, compliance, LUST cleanup

Oklahoma Corporation Commission

PST Scheduling (Equipment Tests)

Schedule witnessed tests: drop tubes, overfill, spill buckets, containment sumps

Oklahoma Department of Agriculture

Food & Forestry (ODAFF) - Weights & Measures

Meter calibration, pump inspections, service tech registration

Oklahoma Department of Environmental Quality

DEQ - Land Protection Division

Stormwater permits, spill reporting, environmental compliance

Oklahoma State Fire Marshal

Fire Prevention Division

Fire code compliance, aboveground storage tanks

Other States

Compliance requirements vary by state. Check these guides for neighboring states.